vtpp2top.gif (10976 bytes)

           [Home]   [Line Card]   [Hot Deals]   [New Products]   [Ordering]   [Events]

Tektronix
 
wvr.jpg (5821 bytes)

Tektronix WVR7120
Multi-Format Multi-Standard Waveform Rasterizer Unit

White Text showing below that is boxed in GREEN
denotes a fully loaded configuration.  Call VTP for additional information and to review additional details regarding performance and configuration not showing here.   Repair service options, calibration service options, VGA display (sold separately from 3rd party Manufacturers), and report options are not shown.

Note: photo shows a fully optioned unit with VGA Monitor (not included)

VTP CONFIGURATION GUIDE
Call VTP at (818) 566-9898 for details

Item Number

Description

WVR7120

SD Waveform Base Rasterizer Unit (1RU); 2 SD standard passive loop through inputs with auto detect clock (525/59.94 or 625/50).  EIA608 VANC Decode as basic text.  Alarm and log if CC is missing. Display the CC as basic text mode, display V-chip overlaid on the picture (monitor mode), or in Status, Alarm, or Error screens (as appropriate).  ANC data support (also for data that conforms to Japan ARIB standards).  1024x768 XGA display monitor output (Display Monitor not included). No analog or digital audio monitoring beyond embedded audio PCM presence, no analog audio I/O in base unit.

Options:

HD
Upgrade when not on inital order or part of a package on intital order is WVR712UP HD

Part of
BAS Option
Package, on
Factory
Initial Order

Part of
PER Option
Package, on
Factory
Initial Order
Part of
ALY Option
Package, on
Factory
Initial Order
Enables 2 SDI input capability to be HD-SDI (not adding additional physical inputs) for high definition monitoring, adds EIA608 VANC portion of EIA708 Decode as basic text.
CPS
No upgrade is possible, factory initial order only
Part of
BAS Option
Package, on
Factory
Initial Order
Part of
PER Option
Package, on
Factory
Initial Order
Part of
ALY Option
Package, on
Factory
Initial Order
Factory initial order configuration Only, adds 2 physical analog composite passive loop-through inputs for composite analog monitoring (upgrade retrofit is not possible), no upgrade option.  EIA-608 Line 21 CC Monitoring.
SIM
Upgrade when not on inital order or part of a package on intital order is WVR712UP SIM
Part of
BAS Option
Package, on
Factory
Initial Order
Part of
PER Option
Package, on
Factory
Initial Order
Part of
ALY Option
Package, on
Factory
Initial Order
Allows User to Select and view two inputs at same time in tile display, versus only one otherwise (some limitations still apply).
AVD
Upgrade when not on inital order or part of a package on intital order is WVR712UP AVD
NOT in BAS package NOT in PER package Part of
ALY Option
Package, on
Factory
Initial Order
Audio Video Delay Auto Measure (proprietary Tektronix out of service measure, requires OFE TG700 with signals provided from either the DVG7 or HDVG7 modules with A/V Timing Mode enabled).
DL
Upgrade when not on inital order or part of a package on intital order is WVR712UP DL

NOT in BAS package NOT in PER package NOT in ALY package Enables 2 HD-SDI input capability to be Dual Link Input for YCbCR or RGB Dual Link Monitoring.  This option is the only option that is not currently part of any Options package for special savings.

Jitter & Physical Layer Options (select one of these two Options only):

EYE
Upgrade when not on inital order or part of a package on intital order is WVR712UP EYE

NOT in BAS package

NOT in PER package Part of
ALY Option
Package, on
Factory
Initial Order
because it is
part of the PHY
Option.
Manual Eye Parameters Measurement, and Physical Layer Status Display of Timing and Alignment. Jitter Waveform Display.  Multiple Pass Filters. Digital Cursors for enabling measurements with numeric basic jitter values, source signal level, cable loss, approximate cable length.  Error Alarm Log with time code stamp.  Multiple eye patterns are capable of being displayed in separate tiles (when combined with SIM Option).
PHY
Upgrade when not on inital order or part of a package on intital order is WVR712UP PHY
NOT in BAS package NOT in PER package Part of
ALY Option
Package, on
Factory
Initial Order
(also includes EYE)
Includes capabilities of EYE option and adds PHY Automated Enhanced Eye Parameters Measurement. Auto function lists enhanced component digital eye parameters numeric value measurement results of eye amplitude, eye rise time, eye fall time, eye rise-fall difference.

Audio Options (select one only):

AD
Upgrade when not on inital order or part of a package on intital order is WVR712UP AD

Part of
BAS Option
Package, on
Factory
Initial Order

Part of
PER Option
Package, on
Factory
Initial Order
Part of
ALY Option
Package, on
Factory
Initial Order
Adds Analog Audio I/O & PCM Digital Audio (embedded and AES/EBU formats). BBC PPM audio scales for analog audio. Breakout cable OPT62 not included (an additional $725).  Adds basic enhanced support for Digital Audio Monitoring in embedded and AES/EBU formats (note: Dolby Decoding of any kind is not possible with the WVR7020 unit).  Simple Dolby presence indication only.  New Audio Loudness (Level EQ) Monitoring, Audio Packet Display (displays information on audio frame number, sample rate, number of active channels, and accumulated processing delay), BBC PPM audio scales for digital audio.
DDE
Upgrade when not on inital order or part of a package on intital order is WVR712UP DDE
NOT Part of
BAS Option
Package
Part of
PER Option
Package, on
Factory
Initial Order
Part of
ALY Option
Package, on
Factory
Initial Order
Includes AD option capability, adds support for Dolby Digital Audio AC-3 Decode to single pair LT/RT Dolby Pro Logic Mix (no Lfe), or LO/RO standard stereo signal (no Lfe), or Mono sum (e.g., LCR/Ls/Rs, no Lfe) Analog Audio, and Dolby E Decode to 8 Ch Analog Audio. Level Meters include Channel 9 and 10. Channel order of the level bars is mapped per SMPTE 320M, or per user preference. Select between phase and surround display.  Breakout cable OPT62 not included.

As showing above, Special Options Packages exist for factory initial orders:

BAS Package

Factory initial order configuration only for this cost-savings package for HD + CPS + SIM + AD.  Options showing above, color coded with this color, are the components of the BAS Package.

PER Package

Factory initial order configuration only for everything in BAS Package + DDE.  Options showing above, color coded with this color, are the components of the BAS Package.

ALY Package

Factory initial order configuration only for everything in BAS Package + DDE + AVD + PHY + DAT. Options showing above,  color coded with this color, are the components of the ALY Package.

Special Options Other then DL that are not in any Packages:

62

Analog Audio Breakout Cable for options AD, or DDE – 6 ft. Male 62 Pin D Connector to 8XLR Male Outputs and 12XLR Female Inputs

Tektronix Field Service upgrades in the Los Angeles area by Tektronix personnel are an additional labor minimum.
Remote Control Panel is at additional cost (not showing).

*VTP is certified to support sales of the MTM400 MPEG Transport Stream Monitor, and to demonstrate and support sales of Cerify Lite Content Verification Software.

Updated 11/19/07