Item Number |
Description |
WVR7120 |
SD Waveform Base Rasterizer Unit (1RU); 2 SD standard passive loop through inputs with auto detect clock (525/59.94 or 625/50). EIA608 VANC Decode as basic text. Alarm and log if CC is missing. Display the CC as basic text mode, display V-chip overlaid on the picture (monitor mode), or in Status, Alarm, or Error screens (as appropriate). ANC data support (also for data that conforms to Japan ARIB standards). 1024x768 XGA display monitor output (Display Monitor not included). No analog or digital audio monitoring beyond embedded audio PCM presence, no analog audio I/O in base unit. |
Options for 1.485Gb/s Configuration (3Gb/s is not possible on this product): |
HD
Upgrade when not on initial order or part of a package on initial order is WVR712UP HD |
Part of
BAS Option
Package, on
Factory
Initial Order |
Part of
ALY Option
Package, on
Factory
Initial Order |
Enables 2 SDI input capability to be HD-SDI 1.485Gb/s (not adding additional physical inputs, just accepting the SD clocks and the 1.485Gb/s HD clock) for high definition monitoring, adds EIA608 VANC portion of EIA708 Decode as basic text. |
CPS
No upgrade is possible, factory initial order only |
Part of
BAS Option
Package, on
Factory
Initial Order |
Part of
ALY Option
Package, on
Factory
Initial Order |
Factory initial order configuration Only, adds 2 physical analog composite passive loop-through inputs for composite analog monitoring (upgrade retrofit is not possible), no upgrade option. EIA-608 Line 21 CC Monitoring. |
SIM
Upgrade when not on initial order or part of a package on initial order is WVR712UP SIM |
Part of
BAS Option
Package, on
Factory
Initial Order |
Part of
ALY Option
Package, on
Factory
Initial Order |
Allows User to Select and view two inputs at same time in tile display, versus only one otherwise (some limitations still apply). |
AVD
Upgrade when not on initial order or part of a package on initial order is WVR712UP AVD |
NOT in BAS package |
Part of
ALY Option
Package, on
Factory
Initial Order |
Audio Video Delay Auto Measure (AUDIO OPTION AD OR DDE IS ALSO REQUIRED). Proprietary Tektronix out of service measure, requires OFE TG700 with signals provided from either the DVG7 or HDVG7 modules with A/V Timing Mode enabled. |
DL
Upgrade when not on initial order or part of a package on initial order is WVR712UP DL |
NOT in BAS package |
NOT in ALY package |
Enables 2 HD-SDI input capability to be Dual Link Input for YCbCR or RGB Dual Link Monitoring. (OPTION HD IS ALSO REQUIRED). This option is the only option that is not currently part of any Options package for special savings. |
Jitter & Physical Layer Options for 1.485 Gb/s (select EYE or PHY Option): |
EYE
Upgrade when not on initial order or part of a package on initial order is WVR712UP EYE |
NOT in BAS package |
Part of
ALY Option
Package, on
Factory
Initial Order
because it is
part of the PHY
Option. |
Manual Eye Parameters Measurement, and Physical Layer Status Display of Timing and Alignment. Jitter Waveform Display. Multiple Pass Filters. Digital Cursors for enabling measurements with numeric basic jitter values, source signal level, cable loss, approximate cable length. Error Alarm Log with time code stamp. Multiple eye patterns are capable of being displayed in separate tiles (when combined with SIM Option). |
PHY
Upgrade when not on initial order or part of a package on initial order is WVR712UP PHY |
NOT in BAS package |
Part of
ALY Option
Package, on
Factory
Initial Order
(also includes EYE) |
Includes capabilities of EYE option and adds PHY Automated Enhanced Eye Parameters Measurement. Auto function lists enhanced component digital eye parameters numeric value measurement results of eye amplitude, eye rise time, eye fall time, eye rise-fall difference. |
Audio Options (select one only): |
AD
Upgrade when not on initial order or part of a package on initial order is WVR712UP AD |
Part of
BAS Option
Package, on
Factory
Initial Order |
Part of
ALY Option
Package, on
Factory
Initial Order because it is included in Option DDE |
Adds Analog Audio I/O & PCM Digital Audio (embedded and AES/EBU formats). BBC PPM audio scales for analog audio. Breakout cable OPT62 not included (an additional $725). Adds basic enhanced support for Digital Audio Monitoring in embedded and AES/EBU formats. Simple Dolby presence indication only. New Audio Loudness (Level EQ) Monitoring, Audio Packet Display (displays information on audio frame number, sample rate, number of active channels, and accumulated processing delay), BBC PPM audio scales for digital audio. |
DDE
Upgrade when not on initial order or part of a package on initial order is WVR712UP DDE |
NOT Part of
BAS Option
Package |
Part of
ALY Option
Package, on
Factory
Initial Order
(includes Option AD) |
Includes AD option capability, adds support for Dolby Digital Audio AC-3 Decode to single pair LT/RT Dolby Pro Logic Mix (no Lfe), or LO/RO standard stereo signal (no Lfe), or Mono sum (e.g., LCR/Ls/Rs, no Lfe) Analog Audio, and Dolby E Decode to 8 Ch Analog Audio. Level Meters include Channel 9 and 10. Channel order of the level bars is mapped per SMPTE 320M, or per user preference. Select between phase and surround display. Breakout cable OPT62 not included. |
As color coded above, Special Options Packages exist for factory initial orders: |
BAS Package |
Factory initial order configuration only for this cost-savings package for HD + CPS + SIM + AD. Options showing above, color coded with this color, are the components of the BAS Package. |
ALY Package |
Factory initial order configuration only for everything in BAS Package + DDE + AVD + PHY + DAT. Options showing above, color coded with this color, are the components of the ALY Package. |
Special Options Other then DL that are not in any Packages: |
62
|
Analog Audio Breakout Cable for options AD, or DDE – 6 ft. Male 62 Pin D Connector to 8XLR Male Outputs and 12XLR Female Inputs |
Tektronix Field Service upgrades in the Los Angeles area by Tektronix personnel are an additional labor minimum.
Remote Control Panel is at additional cost (not showing). |